<<Previous page ˆˆTop pageˆˆ This page Next page>> Click here for all of the manuals
Megasquirt-3: TunerStudio MS Lite Reference Guide There are two ways that this table can operate depending on the setting "Table is Advance/Retard" When using the recommended setting of "Retard", 0 degrees means to leave the exhaust cam in its rest position When using the compatability setting of "Advance", the table works backwards. 0 degrees means fully retarded 13.19 VVT On/Off Curve The VVT On/Off Curve menu option is only enabled if: • VVT is enabled • AND "On/Off" mode is enabled Clicking Boost/VVT > VVT On/Off Curve displays the following screen:
When RPM is between the minimum and maximum RPMs and the load is above the specified number at that Examples using data shown above: At 2300 RPM (any load) -> VVT is off At 3000 RPM and load is 40kPa -> VVT is off At 3000 RPM and load is 50kPa -> VVT is on At 7000RPM and load is 85kPa -> VVT is off At 7000RPM and load is 95kPa -> VVT is on At 7100RPM (any load) -> VVT is off (c) 2014-8 James Murray 2018-07-08 Page 221/356 | |||