<<Previous page ˆˆTop pageˆˆ This page Next page>> Click here for all of the manuals
Trans control setting up and hardware 4 0 0 0 0 3 0 1 0 1 2 1 1 0 0 0 = ground to TCU, 1 = open circuit to TCU (high). Ground-switching input expected. 5.7.2 Solenoid outputs Gear range 1-2 2-3 4-5 P Off Off On R On Off Off N Off Off On 5 Off Off Off 4 Off Off On 3 On Off * 2 On On * 1 Off On * Off = open circuit from TCU, On = ground output from TCU. Low-side output. * in manual ranges 1,2,3 this solenoid is engaged to enable engine-braking. 5.8 Ford E4OD In use by a small number of customers. This has the choice of either an analogue gear position input or a set of switches. Drive should be defined as The coast clutch connects to 'Solenoid C' output The OD cancel switch connects to input 'Selector D' Built-in gear ratios: 2.71,1.54,1.00,0.71 5.8.1 Selector inputs In switch mode, the table applies. In analogue mode, set the voltages to match the analogue range position Gear Selector Switch mode Voltage A B C P 0 0 0 R 0 0 1 N 0 1 0 D 1 1 1 2 1 0 1 1 1 1 0 0 = ground to TCU, 1 = open circuit to TCU (high). Ground-switching input expected. (c) 2014-15 James Murray 2016-01-26 Page 30/60 | |||