Microsquirt Hardware Guide

Models with a hall effect cam sensor should connect to VR2- and will require a pull-up resistor in the harness.

Typical settings:

Spark mode = IAW Weber

Trigger angle/offset = 0 (adjust with strobe)

Ignition input capture = Falling edge

Spark output = Going High

Number of coils = Depends on application

Some applications use a single high current coil, others use coil-on-plug. External ignitors are likely required.

6.17 Mitsubishi CAS 4/1

Known applications include: 

Mitsubishi 4G91 

Mazda Protege and 323 with optical distributor 

This consists of a Mitsubishi optical CAS. Electrically, the two signals on this CAS are connected the same as a 
hall sensor and require a pair of pull-up resistors in the wiring harness.

Typical settings:

Spark mode = CAS 4/1

Trigger angle/offset = 0 (adjust with strobe)

Ignition input capture = Falling edge

Spark output = Going High

Number of coils = Depends on application

You will need to set the “Angle between main and return” parameter to the distance between edges of the 
optical sensor.

Note that if you are not able to get a stable signal off both edges, you should instead use "Toothed 

Wheel", mode with "Dual wheel" and 4 teeth at cam speed set.

6.18 Mitsubishi 4G63 (and Miata)

Known applications include: 

Mitsubishi 4G63 with distributorless ignition, as used in Eclipse, Galant VR4, and Lancer Evolution 

1990-1997 Mazda MX5 Miata